A Comparison of Seitz and Millipore Membrane Filters for the Enumeration of Fecal Coliforms

Abstract

In a comparison of two commonly used membrane filters for enumerating fecal coliform bacteria it was demonstrated that Seitz type M filters recovered statistically more colonies of bacteria than did Millipore HAWG 047S1 filters from pure cultures of Escherichia coli incubated at 44 °C. The membranes were grown on 0.4 % Teepol agar. On incubation at 37°C no significant discrepancy was found. As a reference method was used pour plating in plate count agar (Difco). It was demonstrated that incubation at 44°C did not per se inhibit propagation of fecal coliforms. Both types of filters examined were sterilized by the manufacturers with ethylene oxide. The discrepancy found can therefore not be due to sterilization procedures.

References

  • Datka, B. J., M. J. Jackson & J. B. Bell: Comparison of autoclave and ethylene oxide-sterilized membrane filters used in water quality studies. Appl. Microbiol. 1974, 28, 474–4811.

    Article  Google Scholar 

  • Lautrop, H.: Gelatin-liquefying Klebsiella strains (Bacterium oxyto- cum Flügge). Acta path, microbiol. scand. 1956, 39, 375–384.

    Article  CAS  Google Scholar 

  • Møller, V.: Simplified tests for some amino acid decarboxylases and the arginine dihydrolase system. Acta path, microbiol. scand. 1955, 36, 158–172.

    Article  Google Scholar 

  • Presswood, W. G. & L. R. Brown: Comparison of Gelman and Millipore membrane filters for enumerating fecal coliform bacteria. Appl. Microbiol. 1973, 26, 332–336.

    Article  CAS  Google Scholar 

  • Schaeffer, D. J., Maxine C. Long & K. G. Janardan: Statistical analysis of the recovery of coliform organisms on Gelman and Millipore membrane filters. Appl. Microbiol. 1974, 28, 695–667.

    Article  Google Scholar 

  • Sladek, K. J., R. V. Suslavich, B. I. Sohn & F.V.F. Dawson: Optimum membrane structures for growth of coliform and fecal coliform organisms. Appl. Microbiol. 1975, 30, 685–691.

    Article  CAS  Google Scholar 

  • Vandundersogelse. Udvidet bakteriologisk drikkevandsundersøgelse. (Examination of water. Advanced bacteriological drinking water examination). Dansk Standard 265.1. June 1974.

    Google Scholar 

Download references

Acknowledgement

The author wants to thank Mrs. Jytte Kristiansen for her enthusiastic assistance in planning and performing the technical work.

Author information

Authors and Affiliations

Authors

Rights and permissions

Reprints and permissions

About this article

Cite this article

Søgaard, H. A Comparison of Seitz and Millipore Membrane Filters for the Enumeration of Fecal Coliforms. Acta Vet Scand 17, 25–31 (1976). https://doi.org/10.1186/BF03547940

Download citation

  • Received:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1186/BF03547940

Keywords