Skip to main content

Table 3 Sensitivity, specificity, positive and negative predictive values of blood sucrose for diagnosis of SQL in horses after administration of 1 g/kg of sucrose via nasogastric intubation

From: Diagnostic accuracy of blood sucrose as a screening test for equine gastric ulcer syndrome (EGUS) in adult horses

Time of sampling (min)

Cut-off (µmol/l)

Disease present

Disease absent

Sp (%)

Se (%)

NPV (%)

PPV (%)

95% CI

95% CI

95% CI

95% CI

45

7.86

54

47

68.1

50.0

54.2

64.3

53–81

36–64

41–67

48–79

90

8.24

54

47

72.3

57.4

59.7

70.5

57–84

43–71

46–72

55–83

  1. SQL squamous lesions, Se sensitivity, Sp specificity, NPV negative predictive value, PPV positive predictive value, 95% CI 95% confidence intervals