Skip to main content

Table 4 Estimated sensitivity (Se) and specificity (Sp) for the digital refractometer at different cut-offs in Brix, 95% confidence intervals are given in brackets in 167 colostrum samples from 19 dairy herds in a specific region in Norway (Ringsaker municipality, Hedmark County)

From: Indirect quantification of IgG using a digital refractometer, and factors associated with colostrum quality in Norwegian Red Cattle

 

Brix 18%

Brix 19%

Brix 20%

Brix 21%

Brix 22%

Brix 23%

Brix 24%

Se

100.0 (92.7–100)

95.9 (86.0–99.5)

91.8 (80.4–97.7)

77.6 (63.4–88.2)

69.4 (54.6–81.7)

55.1 (40.2–69.3)

44.9 (30.7–59.8)

Sp

44.9 (35.7–54.3)

58.5 (49.0–67.5)

67.8 (58.6–76.1)

78.8 (70.3–85.8)

83.1 (75.0–89.3)

91.5 (85.0–95.9)

95.8 (90.4–98.6)

  1. The target condition is identification of high quality colostrum (> 50 g/L) using radial immunodiffusion assay assessment as the gold standard